Selecting a Pressure Gauge per EN 837: Range, Accuracy Class, Nominal Size and Accessories

· 4 min lugemine
Yurii
CAD-automatiseerimise insener

The Bourdon tube gauge is the most common pressure instrument in plant engineering and maintenance. Selection mistakes rarely show immediately – they appear as trembling pointers, permanent zero shifts or a burst measuring element. This post summarises the selection rules of the EN 837 series and works through an example.

A German version of this article is available — switch the language to Deutsch.

:::info Tool With the Bourdon Gauge Configurator you combine nominal size, range, connection, filling and accessories and export a PDF datasheet. :::

The EN 837 series

PartScope
EN 837-1Bourdon tube pressure gauges – dimensions, metrology, requirements and testing
EN 837-2Selection and installation recommendations for pressure gauges
EN 837-3Diaphragm and capsule pressure gauges – dimensions, metrology, requirements and testing

EN 837-2 is the working document for selection; EN 837-1 provides the characteristics of the instruments you choose between.

1. Scale range

The single most important step. A gauge working permanently at full scale fatigues; one that only moves through the first tenth cannot be read accurately. The common recommendation:

LoadingOperating pressure at most
steady3/4 of full scale
fluctuating2/3 of full scale

Full-scale values follow a standard series, for example 0–1 / 1.6 / 2.5 / 4 / 6 / 10 / 16 / 25 / 40 / 60 / 100 bar.

Worked example

Steady operating pressure 6 bar

required full scale ≥ 6 bar / 0.75 = 8 bar → range 0–10 bar

Fluctuating operating pressure 6 bar

required full scale ≥ 6 bar / (2/3) = 9 bar → range 0–10 bar

Fluctuating operating pressure 7 bar

required full scale ≥ 7 bar / (2/3) = 10.5 bar → range 0–16 bar

Half a bar more operating pressure – and the next range up is needed.

2. Accuracy class

The class states the permissible error as a percentage of the span. EN 837-1 defines classes 0.1 – 0.25 – 0.6 – 1 – 1.6 – 2.5 – 4.

Class 1.0 on 0–10 bar → ± 0.1 bar
Class 1.6 on 0–16 bar → ± 0.256 bar

Because the error refers to the span, an oversized range worsens accuracy at the operating point – another reason not to double the range "to be safe".

The fine classes 0.1 to 0.6 are for test and reference gauges; in plant operation 1.0 and 1.6 are typical.

3. Nominal size and connection

The nominal size is the case diameter in millimetres. Standard sizes include 40, 50, 63, 80, 100, 150, 160 and 250. Rule of thumb: the longer the reading distance and the finer the class, the larger the size.

The process connection is typically G ¼ B for small sizes and G ½ B from size 100 upwards, lower mount or back mount. Check the thread type at the installation point – an NPT thread seals differently from a parallel G thread with a sealing ring.

4. Operating conditions and accessories

SituationMeasure
Vibration, pressure surges, pulsationLiquid filling (e.g. glycerine) damps pointer and movement; with strong pulsation add a throttle screw
Steam, hot mediaSiphon: condensate protects the Bourdon tube from the medium temperature
Aggressive, viscous or crystallising mediaDiaphragm seal instead of direct media contact
Replacement during operationFit a gauge isolating valve
Gases and vapours at high pressureChoose a safety pattern per EN 837-1
OxygenInstrument free of oil and grease, marked accordingly

The highest safety pattern, S3, has a solid baffle wall between measuring element and dial and a blow-out back: if the Bourdon tube fails, the medium escapes to the rear instead of through the window towards the operator.

Checklist for datasheet and order

  • Medium, operating pressure, loading (steady / fluctuating)
  • Range per the 3/4 or 2/3 rule
  • Accuracy class
  • Nominal size and reading distance
  • Connection thread and position
  • Wetted materials of measuring element and connection
  • Filling, safety pattern
  • Accessories: isolating valve, siphon, throttle screw, diaphragm seal
  • Measuring point tag

The Bourdon Gauge Configurator captures exactly these items and summarises them in a PDF datasheet.

:::caution Note This post summarises common selection rules and does not replace the current editions of EN 837-1 to -3 or manufacturer data. Safety-related measuring points are additionally subject to the plant design requirements. :::

Open the tool: Bourdon Gauge Configurator · Documentation